SEER2
Seasonal Energy Efficiency Ratio 2 — the current U.S. cooling-efficiency rating method used for systems manufactured after 2023. Higher SEER2 generally means lower cooling cost for the same capacity.
Entity definitions used across our residential and commercial guides — so quotes and inspections make sense the first time.
Seasonal Energy Efficiency Ratio 2 — the current U.S. cooling-efficiency rating method used for systems manufactured after 2023. Higher SEER2 generally means lower cooling cost for the same capacity.
Heating Seasonal Performance Factor 2 — the heating-side efficiency rating for heat pumps under the updated test procedure.
Energy Efficiency Ratio — cooling efficiency at a single outdoor design condition. Useful when comparing peak-load performance in hot inland valleys.
British Thermal Unit — a measure of heating or cooling capacity. Residential systems are often discussed in tons (1 ton ≈ 12,000 BTU/h).
Annual Fuel Utilization Efficiency — how efficiently a gas furnace converts fuel into heat over a typical season.
Minimum Efficiency Reporting Value — filter efficiency scale. Higher MERV captures finer particles; confirm your blower can handle the pressure drop.
The common residential refrigerant being phased down. New equipment is shifting to lower-GWP alternatives in California.
A lower-GWP A2L refrigerant used in many next-generation residential systems replacing R-410A.
A lower-GWP A2L refrigerant used by some manufacturers as an R-410A successor.
Electronically commutated motor — variable-speed blower that improves comfort, humidity control, and efficiency versus single-speed PSC motors.
Indoor coil where refrigerant absorbs heat from indoor air during cooling.
Outdoor unit heat exchanger that rejects heat outdoors during cooling (and absorbs heat outdoors during heat-pump heating).
The pump that circulates refrigerant and creates the pressure difference that drives heat transfer.
A system that moves heat rather than generating it with combustion — cooling in summer and heating in winter from one outdoor unit.
A duct-free heat pump with one outdoor unit and one or more indoor heads — common for additions, upstairs zones, and homes without usable ducts.
The sheet-metal box attached to the air handler or furnace that distributes supply air into the duct trunks.
Air pulled from the living space back to the system to be conditioned again.
Conditioned air delivered from the system into rooms through supply registers.
Industry load-calculation method used to size heating and cooling equipment for a specific home — not a rule-of-thumb tonnage guess.
California Energy Code requirements that affect HVAC changeouts, including efficiency, controls, and documentation.
Home Energy Rating System field verification required on many California HVAC changeouts to confirm duct leakage, airflow, and refrigerant charge.
Outdoor temperature where a heat pump's heat output equals the home's heat loss — below that, supplemental heat may be needed.
Compressor that modulates capacity instead of only on/off — better humidity control and steadier comfort.
Furnace gas valve that varies flame output for finer temperature control and quieter operation.
The refrigeration cycle used by air conditioners and heat pumps: compress, condense, expand, evaporate.
Get fast, precise heating & cooling from Precision Heating & Cooling in English or Spanish. Se habla español. Perfection Guaranteed — call now or request service online.